PWM Control IC

AC/DC用PWM控制器型DC/DC轉換器BM1P067FJ為所有存在介面的產品提供最佳的系統。內建650V耐壓啟動電路,有助於實現低功耗。絕緣、非絕緣均可對應,可輕鬆設計各種形式的低功耗轉換器。外接開關用MOSFET及電流檢測電阻,可實現高自由度的電源設計。開關頻率採用固定方式。使用電流模式控制,進行逐週期電流限制,發揮內建寬和暫態響應的優異性能。輕負載時降低頻率,實現高效率。內建跳頻功能,有助於實現低EMI。內建了緩啟動功能、脈衝串功能、逐週期過電流限制、VCC過電壓保護、過負載保護等各種保護功能。

Data Sheet 購買 *
* 本產品是標準級的產品。
本產品不建議使用的車載設備。

Product Detail

 
料號 | BM1P067FJ-E2
狀態 | 推薦品
封裝 | SOP-J8
單位數量 | 2500
最小包裝數量 | 2500
包裝形式 | Taping
RoHS | Yes

規格:

FB OLP

Auto Restart

BR UVLO

No

External LATCH Function

No

AC Monitor Function

No

VH Terminal UVLO

No

Over Current Detection Voltage (typ.)[V]

0.4

Dynamic Over Current Detection

No

Frequency Reduction Function

Yes

Current Detection Resistors

External

FET

External

Controller Type

PWM

Vin1(Min.)[V]

8.9

Vin1(Max.)[V]

26.0

Withstand Voltage [V]

650

SW Frequency (Max.)[kHz]

65.0

VCC OVP

Auto Restart

BR PIN

No

Channel

1

Light Load mode

Yes

EN

No

Soft Start

Yes

Thermal Shut-down

Auto Restart

Under Voltage Lock Out

Yes

Operating Temperature (Min.)[°C]

-40

Operating Temperature (Max.)[°C]

85

Package Size [mm]

4.9x6 (t=1.65)

功能:

· PWM current mode method
· Frequency Hopping function
· Burst operation / Frequency reduction function when load is light
· Built-in 650V start circuit
· VCC pin under voltage protection
· VCC pin over voltage protection
· CS pin Open protection
· CS pin Leading-Edge-Blanking function
· Per-cycle over current protection circuit
· Current protection with AC voltage compensation
· Soft start
· Secondary Over current protection circuit

Design Resources

 

Technical Articles

Schematic Design & Verification

  • Importance of Probe Calibration When Measuring Power: Deskew
  • Impedance Characteristics of Bypass Capacitor

Thermal Design

  • What Is Thermal Design
  • Method for Calculating Junction Temperature from Transient Thermal Resistance Data
  • Thermal Resistance

Tools

2D/3D/CAD

  • SOP-J8 Footprint / Symbol
  • SOP-J8 3D STEP Data

Packaging & Quality

Package Information

  • Package Information
  • Anti-Whisker formation

Manufacturing Data

  • Factory Information

Environmental Data

  • UL94 Flame Classifications of Mold Compound
  • Compliance with the ELV directive
  • REACH SVHC Non-use Declaration
  • RoHS Comission Delegated Directive

Export Information

  • The Export Control Order
  • Export Administration Regulations(EAR)